Watch The PURE WATER

Watch The PURE WATER

1267 bookmarks
Custom sorting
Two-dimensional correlation optimized warping algorithm for aligning GC x GC-MS data - PubMed
Two-dimensional correlation optimized warping algorithm for aligning GC x GC-MS data - PubMed
A two-dimensional (2-D) correlation optimized warping (COW) algorithm has been developed to align 2-D gas chromatography coupled with time-of-flight mass spectrometry (GC x GC/TOF-MS) data. By partitioning raw chromatographic profiles and warping the grid points simultaneously along the first and se …
·pubmed.ncbi.nlm.nih.gov·
Two-dimensional correlation optimized warping algorithm for aligning GC x GC-MS data - PubMed
Chemometric assisted correlation optimized warping of chromatograms: optimizing the computational time for correcting the drifts in chromatographic peak positions - Analytical Methods (RSC Publishing)
Chemometric assisted correlation optimized warping of chromatograms: optimizing the computational time for correcting the drifts in chromatographic peak positions - Analytical Methods (RSC Publishing)
Correlation optimized warping has been the most used technique to correct the drifts in peak positions. COW aligns the unaligned chromatogram to the reference chromatogram provided slack (t) and segment lengths (m) are optimized. However, several combinations of m and t need to be tested before finding the o
·pubs.rsc.org·
Chemometric assisted correlation optimized warping of chromatograms: optimizing the computational time for correcting the drifts in chromatographic peak positions - Analytical Methods (RSC Publishing)
Server Not Found
Server Not Found
I have a Financial Time Series from a database and intend to cluster the time series based on their similarity. How would it be different to cluster them based on their pairwise Correlation and clu...
·stats.stackexchange.com·
Server Not Found
A comparison of three algorithms for chromatograms alignment - PubMed
A comparison of three algorithms for chromatograms alignment - PubMed
In this paper the performance of three alignment algorithms, correlation optimized warping, parametric time warping and semi-parametric time warping, is compared on real chromatograms. Among these, parametric time warping is the simplest and fastest; generally less than 1s is required to align two c …
·pubmed.ncbi.nlm.nih.gov·
A comparison of three algorithms for chromatograms alignment - PubMed
Matching colonic polyps using correlation optimized warping, Proceedings of SPIE | 10.1117/12.844352 | DeepDyve
Matching colonic polyps using correlation optimized warping, Proceedings of SPIE | 10.1117/12.844352 | DeepDyve
Computed tomographic colonography (CTC) combined with a computer aided detection system has the potential for improving colonic polyp detection and increasing the use of CTC for colon cancer screening. In the clinical use of CTC, a true colonic polyp will be confirmed with high confidence if a radiologist can find it on both the supine and prone scans. To assist radiologists in CTC reading, we propose a new method for matching polyp findings on the supine and prone scans. The method performs a colon registration using four automatically identified anatomical salient points and correlation optimized warping (COW) of colon centerline features. We first exclude false positive detections using prediction information from a support vector machine (SVM) classifier committee to reduce initial false positive pairs. Then each remaining CAD detection is mapped to the other scan using COW technique applied to the distance along the centerline in each colon. In the last step, a new SVM classifier is applied to the candidate pair dataset to find true polyp pairs between supine and prone scans. Experimental results show that our method can improve the sensitivity to 0.87 at 4 false positive pairs per patient compared with 0.72 for a competing method that uses the normalized distance along the colon centerline (p
·deepdyve.com·
Matching colonic polyps using correlation optimized warping, Proceedings of SPIE | 10.1117/12.844352 | DeepDyve
MSIWarp: A General Approach to Mass Alignment in Mass Spectrometry Imaging | Analytical Chemistry
MSIWarp: A General Approach to Mass Alignment in Mass Spectrometry Imaging | Analytical Chemistry
Mass spectrometry imaging (MSI) is a technique that provides comprehensive molecular information with high spatial resolution from tissue. Today, there is a strong push toward sharing data sets through public repositories in many research fields where MSI is commonly applied; yet, there is no standardized protocol for analyzing these data sets in a reproducible manner. Shifts in the mass-to-charge ratio (m/z) of molecular peaks present a major obstacle that can make it impossible to distinguish one compound from another. Here, we present a label-free m/z alignment approach that is compatible with multiple instrument types and makes no assumptions on the sample’s molecular composition. Our approach, MSIWarp (https://github.com/horvatovichlab/MSIWarp), finds an m/z recalibration function by maximizing a similarity score that considers both the intensity and m/z position of peaks matched between two spectra. MSIWarp requires only centroid spectra to find the recalibration function and is thereby readily applicable to almost any MSI data set. To deal with particularly misaligned or peak-sparse spectra, we provide an option to detect and exclude spurious peak matches with a tailored random sample consensus (RANSAC) procedure. We evaluate our approach with four publicly available data sets from both time-of-flight (TOF) and Orbitrap instruments and demonstrate up to 88% improvement in m/z alignment.
·pubs.acs.org·
MSIWarp: A General Approach to Mass Alignment in Mass Spectrometry Imaging | Analytical Chemistry
Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data, Journal of Chemometrics | 10.1002/cem.859 | DeepDyve
Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data, Journal of Chemometrics | 10.1002/cem.859 | DeepDyve
Two different algorithms for time‐alignment as a preprocessing step in linear factor models are studied. Correlation optimized warping and dynamic time warping are both presented in the literature as methods that can eliminate shift‐related artifacts from measurements by correcting a sample vector towards a reference. In this study both the theoretical properties and the practical implications of using signal warping as preprocessing for chromatographic data are investigated. The connection between the two algorithms is also discussed. The findings are illustrated by means of a case study of principal component analysis on a real data set, including manifest retention time artifacts, of extracts from coffee samples stored under different packaging conditions for varying storage times. We concluded that for the data presented here dynamic time warping with rigid slope constraints and correlation optimized warping are superior to unconstrained dynamic time warping; both considerably simplify interpretation of the factor model results. Unconstrained dynamic time warping was found to be too flexible for this chromatographic data set, resulting in an overcompensation of the observed shifts and suggesting the unsuitability of this preprocessing method for this type of signals. Copyright © 2004 John Wiley & Sons, Ltd.
·deepdyve.com·
Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data, Journal of Chemometrics | 10.1002/cem.859 | DeepDyve
Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis
Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis
Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice—Once supine and once prone—to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated ...
·ncbi.nlm.nih.gov·
Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis
Correlation-optimized time warping for motion | SpringerLink
Correlation-optimized time warping for motion | SpringerLink
The Visual Computer - Retrieval and comparative editing/modeling of motion data require temporal alignment. In other words, for such processes to perform accurately, critical features of motion...
·link.springer.com·
Correlation-optimized time warping for motion | SpringerLink
Analysis of Volatile Organic Compounds in Exhaled Breath by Gas Chromatography-Mass Spectrometry Combined with Chemometric Analysis | SpringerLink
Analysis of Volatile Organic Compounds in Exhaled Breath by Gas Chromatography-Mass Spectrometry Combined with Chemometric Analysis | SpringerLink
Analysis of exhaled breath samples reveals the presence of many volatile organic compounds (VOCs). The VOC composition of the breath, the so-called breath profile, contains a variety of information...
·link.springer.com·
Analysis of Volatile Organic Compounds in Exhaled Breath by Gas Chromatography-Mass Spectrometry Combined with Chemometric Analysis | SpringerLink
Application of Dynamic Time Warping to the Quality Evaluation of Radix Puerariae thomsonii: Correcting Retention Time Shift in the Chromatographic Fingerprints | Journal of Chromatographic Science | Oxford Academic
Application of Dynamic Time Warping to the Quality Evaluation of Radix Puerariae thomsonii: Correcting Retention Time Shift in the Chromatographic Fingerprints | Journal of Chromatographic Science | Oxford Academic
Abstract. The application of dynamic time warping (DTW) to the correction of retention time shift in chromatographic fingerprints of Radix Puerariae thomsonii (
·academic.oup.com·
Application of Dynamic Time Warping to the Quality Evaluation of Radix Puerariae thomsonii: Correcting Retention Time Shift in the Chromatographic Fingerprints | Journal of Chromatographic Science | Oxford Academic
Chemical Fingerprinting of Petroleum Biomarkers Using Time Warping and PCA | Environmental Science & Technology
Chemical Fingerprinting of Petroleum Biomarkers Using Time Warping and PCA | Environmental Science & Technology
A new method for chemical fingerprinting of petroleum biomakers is described. The method consists of GC-MS analysis, preprocessing of GC-MS chromatograms, and principal component analysis (PCA) of selected regions. The preprocessing consists of baseline removal by derivatization, normalization, and alignment using correlation optimized warping. The method was applied to chromatograms of m/z 217 (tricyclic and tetracyclic steranes) of oil spill samples and source oils. Oil spill samples collected from the coastal environment in the weeks after the Baltic Carrier oil spill were clustered in principal components 1 to 4 with oil samples from the tank of the Baltic Carrier (source oil). The discriminative power of PCA was enhanced by deselecting the most uncertain variables or scaling them according to their uncertainty, using a weighted least squares criterion. The four principal components were interpreted as follows:  boiling point range (PC1), clay content (PC2), carbon number distribution of sterols in the source rock (PC3), and thermal maturity of the oil (PC4). In summary, the method allows for analyses of chromatograms using a fast and objective procedure and with more comprehensive data usage compared to other fingerprinting methods.
·pubs.acs.org·
Chemical Fingerprinting of Petroleum Biomarkers Using Time Warping and PCA | Environmental Science & Technology
Prediction of Total Phenolic Content in Extracts of Prunella Species from HPLC Profiles by Multivariate Calibration
Prediction of Total Phenolic Content in Extracts of Prunella Species from HPLC Profiles by Multivariate Calibration
The multivariate calibration methods—principal component regression (PCR) and partial least squares (PLSs)—were employed for the prediction of total phenol contents of four Prunella species. High performance liquid chromatography (HPLC) and spectrophotometric approaches were used to determine the total phenol content of the Prunella samples. Several preprocessing techniques such as smoothing, normalization, and column centering were employed to extract the chemically relevant information from the data after alignment with correlation optimized warping (COW). The importance of the preprocessing was investigated by calculating the root mean square error (RMSE) for the calibration set of the total phenol content of Prunella samples. The models developed based on the preprocessed data were able to predict the total phenol content with a precision comparable to that of the reference of the Folin-Ciocalteu method. PLS model seems preferable, because of its predictive and describing abilities and good interpretability of the contribution of compounds to the total phenol content. Multivariate calibration methods were constructed to model the total phenol content of the Prunella samples from the HPLC profiles and indicate peaks responsible for the total phenol content successfully.
·hindawi.com·
Prediction of Total Phenolic Content in Extracts of Prunella Species from HPLC Profiles by Multivariate Calibration
Bifidobacterial Succession and Correlation Networks in a Large Unselected Cohort of Mothers and Their Children | Applied and Environmental Microbiology
Bifidobacterial Succession and Correlation Networks in a Large Unselected Cohort of Mothers and Their Children | Applied and Environmental Microbiology
Bifidobacteria are a major microbial component of infant gut microbiota, which is believed to promote health benefits for the host and stimulate maturation of the immune system. Despite their perceived importance, very little is known about the natural development of and possible correlations between bifidobacteria in human populations. To address this knowledge gap, we analyzed stool samples from a randomly selected healthy cohort of 87 infants and their mothers with >90% of vaginal delivery and nearly 100% breast-feeding at 4 months. Fecal material was sampled during pregnancy, at 3 and 10 days, at 4 months, and at 1 and 2 years after birth. Stool samples were predicted to be rich in the species Bifidobacterium adolescentis, B. bifidum, B. dentium, B. breve, and B. longum. Due to high variation, we did not identify a clear age-related structure at the individual level. Within the population as a whole, however, there were clear age-related successions. Negative correlations between the B. longum group and B. adolescentis were detected in adults and in 1- and 2-year-old children, whereas negative correlations between B. longum and B. breve were characteristic for newborns and 4-month-old infants. The highly structured age-related development of and correlation networks between bifidobacterial species during the first 2 years of life mirrors their different or competing nutritional requirements, which in turn may be associated with specific biological functions in the development of healthy gut.
·aem.asm.org·
Bifidobacterial Succession and Correlation Networks in a Large Unselected Cohort of Mothers and Their Children | Applied and Environmental Microbiology
preprocess 5. Automating alignment - YouTube
preprocess 5. Automating alignment - YouTube
Here we will show how to automatically find good settings for correlation optimized warping (COW). Code used in the video: %% Prepare data % Data available at https://bit.ly/2uvYtLp load WARP_GC_TIC.mat X = Xtic.data(:,2040:3130); optim_space = [5 100 2 10]; options = [0 3 50 .15]; ref = ref_select(X,[],[1 1]); %% Run the optimization [optim_pars,OS,diagnos] = optim_cow(X,optim_space,options,ref); %% [Warping,XWarped,Diagnos] = cow(ref,X,53,4); %% ax(1) = subplot(2,1,1); plot(XWarped') title('Warped'); axis tight ax(2)=subplot(2,1,2) plot(X'); title('Raw') axis tight shg linkaxes(ax,'xy'); shg
·youtube.com·
preprocess 5. Automating alignment - YouTube