Found 120 bookmarks
Custom sorting
How do I calculate the gas concentration in PPM?
How do I calculate the gas concentration in PPM?
I have asked two times the following question:I want to calculate the gas concentration, in ppm, in the closed chamber of volume 1025 cm3. I have a cylinder of mixture of NH3 and air with the 10...
·www.researchgate.net·
How do I calculate the gas concentration in PPM?
CO2 Gas Concentration Defined
CO2 Gas Concentration Defined
When measuring gases like carbon dioxide, oxygen, or methane, the term concentration is used to describe the amount of gas by volume in the air. The 2 most common units of measurement are parts-per
·www.co2meter.com·
CO2 Gas Concentration Defined
Fish Tank Air Flow rate
Fish Tank Air Flow rate
Depth that tube is submerged makes significant difference.
·fishlab.com·
Fish Tank Air Flow rate
Organic films on atmospheric aerosol particles, fog droplets, cloud droplets, raindrops, and snowflakes
Organic films on atmospheric aerosol particles, fog droplets, cloud droplets, raindrops, and snowflakes
******!!!!!******** "Organic films are probably common on atmospheric aerosol particles and that they may occur under certain circumstances on fog droplets, cloud droplets, and snowflakes. If present, they will increase the lifetimes of aerosol particles, fog droplets, and cloud droplets, both by inhibiting water vapor evaporation and by reducing the efficiency with which these atmospheric components are scavenged. The presence of the films will not cause a significant reduction of solar radiation within the aqueous solution. It appears likely, however, that the transport of gaseous molecules into and out of the aqueous solution will be impeded by factors of several hundred or more when organic films are present. Since incorporated gas molecules provide much of the oxidizing potential of atmospheric water droplets, the organic films will play a major role in droplet chemistry by strongly inhibiting solution oxidation."
·agupubs.onlinelibrary.wiley.com·
Organic films on atmospheric aerosol particles, fog droplets, cloud droplets, raindrops, and snowflakes
CN107494588A - A kind of slow-release solid chlorine dioxide propellant and preparation method thereof - Google Patents
CN107494588A - A kind of slow-release solid chlorine dioxide propellant and preparation method thereof - Google Patents
The invention discloses a kind of smell is thin, strength properties are stable, the duration is long, slow-release solid chlorine dioxide propellant easy to use and preparation method thereof.Slow-release solid chlorine dioxide propellant is made up of the component of following mass fraction:15~25 parts of sodium chlorite, 10~20 parts of urea nitrate, 40~50 parts of medical stone, 4~8 parts of magnesium sulfate, 4~8 parts of calcium sulfate, 3~8 parts of super absorbent resin, 2~6 parts of beta cyclodextrin.Its preparation method is:Medical stone is broken into little particle, activated ...
·patents.google.com·
CN107494588A - A kind of slow-release solid chlorine dioxide propellant and preparation method thereof - Google Patents
Permissible exposure limit - Wikipedia
Permissible exposure limit - Wikipedia
"A TWA is the average exposure over a specified period, usually a nominal eight hours. This means that, for limited periods, a worker may be exposed to concentration excursions higher than the PEL, so long as the TWA is not exceeded and any applicable excursion limit is not exceeded. An excursion limit typically means that "...worker exposure levels may exceed 3 times the PEL-TWA for no more than a total of 30 minutes during a workday, and under no circumstances should they exceed 5 times the PEL-TWA, provided that the PEL-TWA is not exceeded."...A short-term exposure limit is one that addresses the average exposure over a 15-30 minute period of maximum exposure during a single work shift. A ceiling limit is one that may not be exceeded for any time"
·en.wikipedia.org·
Permissible exposure limit - Wikipedia
Calculation methods used under the air contaminants standard for extended work shifts. | Occupational Safety and Health Administration
Calculation methods used under the air contaminants standard for extended work shifts. | Occupational Safety and Health Administration
" I have assumed that you are speaking to the permissible exposure limit (PEL) for a single air contaminant over an extended workshift rather than calculating a PEL for multiple chemical exposures with synergistic or additive effects. OSHA has only two standards that specifically allow an adjustment to the PEL based upon the number of hours worked. Those two standards include 29 CFR 1910.1025 and 1926.62 - both for occupational lead exposure. No other OSHA PEL has taken this approach. All of the other OSHA PELs are based upon an 8-hour time weighted average (TWA) exposure limit, a short term exposure limit (STEL) or a ceiling exposure limit. Some contaminants may have multiple exposure limits depending upon the nature of the hazardous chemical."
·osha.gov·
Calculation methods used under the air contaminants standard for extended work shifts. | Occupational Safety and Health Administration
Inhibition of Hyphal Growth of the Fungus Alternaria alternata by Chlorine Dioxide Gas at Very Low Concentrations
Inhibition of Hyphal Growth of the Fungus Alternaria alternata by Chlorine Dioxide Gas at Very Low Concentrations
****!!!!****!!! "The efficacy of chlorine dioxide (ClO(2)) gas at very low concentrations for hyphal growth of Alternaria alternata related to fungal allergy was evaluated using a fungus detector. The fungus detector is a plastic sheet with a drop of spore-suspending medium, and it makes possible clear observations of hyphal growth with a light microscope. ClO(2) gas (average 0.075 ppm, 0.21 microg/l) inhibited hyphal growth of the fungus, but not germination of fungal spores. The hyphal length was more than 1780 mum under air conditions (control) and 49+/-17 microm under ClO(2) gas conditions for 72 h. According to the international chemical safety card, threshold limit values for ClO(2) gas are 0.1 ppm as an 8-h time-weight average and 0.3 ppm as a 15 min short-term exposure limit. From these data, we propose that treatment with ClO(2) gas at very low concentrations in space is a useful tool for the growth inhibition of fungi in the fields of food, medicine, etc. without adverse effects."
·pdfs.semanticscholar.org·
Inhibition of Hyphal Growth of the Fungus Alternaria alternata by Chlorine Dioxide Gas at Very Low Concentrations
Japan companies punished over dodgy 'antibacterial' labels
Japan companies punished over dodgy 'antibacterial' labels
"administrative punishments last month on 17 companies for... exaggerating the effects of their pharmaceutical products that supposedly sterilize living spaces. The agency said the companies failed to present reasonable data"
·www.asiaone.com·
Japan companies punished over dodgy 'antibacterial' labels
EP2554513A1 - Device for generating chlorine dioxide - Google Patents
EP2554513A1 - Device for generating chlorine dioxide - Google Patents
{Chlorite granules activated by UV-LED lights. Taiko} Provided is a device for generating chlorine dioxide which has been miniaturized so that a chlorine dioxide source can be carried and which has no fear of liquid leakage and can be continuously used. A cartridge (28) having a chemical-holding space (29) in which a granular chlorite is held, a fan (24), and ultraviolet LED lamps (32) have been disposed within a device main body (12) which can be separated into two or more detachable portions. The cartridge (28) has light-transmitting properties and has a structure which enables air to pass through the chemical-holding space (29) and the insi...
·patents.google.com·
EP2554513A1 - Device for generating chlorine dioxide - Google Patents
The use of dioxy MP 14 (stabilized aqueous chlorine dioxide) to control environmental airborne microorganisms ~University of the Western Cape
The use of dioxy MP 14 (stabilized aqueous chlorine dioxide) to control environmental airborne microorganisms ~University of the Western Cape
2009 thesis. "Dioxy MP 14 is a locally developed form of stabilized chlorine dioxide in an aqueous medium. It has all the sanitizing properties of chlorine dioxide gas, a neutral compound of chlorine in the +IV oxidation state, which has been used extensively as a non-toxic sterilizing agent with various applications. In this study, Dioxy MP14 was tested in a commercial chicken pen to determine its effectiveness as an environmental sanitizing agent. Control of environmental microbes in a chicken pen is important to ensure healthy birds and optimum egg production. The biocide was introduced via an overhead misting system with a variable dosing pump at various daily frequencies. The effectiveness of environmental microorganism control was determined with air settle plates. The health and performance of the chickens were evaluated and compared to chickens in a control pen. The results show a decrease in airborne microbial load in the treated pen. Better egg production and lower mortality of the chickens in the treated pen compared to the control pen, indicate effective environmental microbial control was achieved with a residual 7.46 ppm Dioxy MP 14 at a daily dose given for 5 minutes every 2 hours. This study was a pilot study, with encouraging results, for an extended study to investigate the feasibility of introducing Dioxy MP 14 through a misting system in a clinical environment (clinics and hospitals) to control airborne pathogens like Mycobacterium tuberculosis thereby reducing the infection risks for clinical workers and medical staff."
·etd.uwc.ac.za·
The use of dioxy MP 14 (stabilized aqueous chlorine dioxide) to control environmental airborne microorganisms ~University of the Western Cape
"Nebulizer" - Apura s.r.l.
"Nebulizer" - Apura s.r.l.
Nebulizer / atomizer for biocides (especially chlorine dioxide Apura line). Simple use and maintenance. Fixed compressed air supply or via portable compressors. Suitable for biocides, fungicides, etc.
·directindustry.com·
"Nebulizer" - Apura s.r.l.
AirDoctor Portable | AirDoctor
AirDoctor Portable | AirDoctor
AirDoctor is a Japanese product that protects against airborne infectious diseases and effectively eliminates the presence of viruses, bacteria, pollen and other microbes.Provides wearer protection for 30 days.
·airdoctor.eu·
AirDoctor Portable | AirDoctor
Statistical evaluation of disinfection performance of chlorine dioxide and WAHW in improving indoor air quality of university library - ScienceDirect
Statistical evaluation of disinfection performance of chlorine dioxide and WAHW in improving indoor air quality of university library - ScienceDirect
**** "single-daily disinfection mode (SM), a twice-daily disinfection mode (TM), and a regular disinfection mode (RM). It is inferred that a higher air velocity is beneficial in spreading the disinfectant within the indoor space and improving the disinfection efficiency as a result."
·sciencedirect.com·
Statistical evaluation of disinfection performance of chlorine dioxide and WAHW in improving indoor air quality of university library - ScienceDirect